Family 16h Processor Functions 5:1Ġ0:02.3 PCI bridge: Advanced Micro Devices, Inc. Device 156bĠ0:02.2 PCI bridge: Advanced Micro Devices, Inc. Device 1567Ġ0:02.0 Host bridge: Advanced Micro Devices, Inc. Device 1566Ġ0:00.2 IOMMU: Advanced Micro Devices, Inc.
OS: Description: Ubuntu 18.04.2 LTS ServerĠ0:00.0 Host bridge: Advanced Micro Devices, Inc.APU3C4 3x Gigabit LAN, Quad Core CPU, 16GB SSD, 4GB RAM.
but I don't know how to troubleshoot further. fails at sudo mmcli -L with error: couldn't get bus: Could not.attempting to use modem-manager to setup the 4g-modem following this.Very short version of the specific problem: The outputs below should describe the details. Specifically Huawei ME909s-120 mini-pcie on APU3 board by pcengine. If you face similar issues then you need not worry, you are just one step away from the Community Forums :).I am trying to get 4G (UK) working on my Ubuntu 18 server. If the above steps did not fix the issue and if something else worked, please post it in the comments section. Now open the Application Catalog, there should be no errors. You could also change the path to the folder v9 and run the command aspnet_regiis.exe /i –enableĪfter executing the above command, restart the IIS using iisreset command. NET Framework version 9, launch the command prompt as administrator and run the following command : %windir%/Microsoft.NET/Framework64/v9/aspnet_regiis.exe /i –enable To fix this you need to enable or activate. For me the below solution fixed the issue and removing the roles was not required. In most of the forums, it is suggested to remove the Application Catalog website point and Application Catalog web service point and reinstall them. When I opened the Application Catalog I found the error cannot connect to the application server.
In most of the cases status code 500 for the Application Catalog web service role is seen when there are problems with IIS or. Next, I checked the log file SMSAWEBSVCSetup.log and found no errors. For more information, refer to Microsoft Knowledge Base. Solution: Verify that the designated Web Site is enabled, and functioning properly. Possible cause: The designated Web Site is disabled in IIS. Solution: Verify that the designated Web Site is configured to use the same ports which AWEBSVC is configured to use. Possible cause: Internet Information Services (IIS) isn’t configured to listen on the ports over which AWEBSVC is configured to communicate. The http status code and text is 500, Internal Server Error. Upon checking status message details, the error description wasĪpplication Web Service Control Manager detected AWEBSVC is not responding to HTTP requests. I found that SMS_AWEBSVC_CONTROL_MANAGER had errors. I checked Monitoring > System Status > Component Status to see if there were any errors on SMS_PORTALWEB_CONTROL_MANAGER and SMS_AWEBSVC_CONTROL_MANAGER. Fix Cannot Connect to the Application Server ErrorĪnyone looking to troubleshoot this issue should start looking at component status first. If this problem continues, contact your help desk”. Try again later to see if the problem has been corrected. The website cannot communicate with the server. “Cannot connect to the application server.
When the user launched the software center, and clicked on find additional applications from the Application Catalog, there was an error. This error was a surprise to me as there were no changes done on Configuration Manager server (as far as i knew). I was working on deploying applications to the users when I came across an error Cannot connect to the application server.